Model NO.: PSG
Size: 500*330*1200
Working Pressrue: 0.6~0.8MPa
Trademark: GAN
Origin: Shenzhen, China
Model NO.: PSG
Size: 500*330*1200
Working Pressrue: 0.6~0.8MPa
Trademark: GAN
Origin: Shenzhen, China
The PSG series Outside foam hydrant cabinet is mainly consist of cabinet, fire hose reel, foam concentrate tank, proportioner, foam gun and dry powder extinguisher. It can either apply in foam extinguishing system or water spray extinguishing system. Close the foam valve and put out the fire with water when applied as water spray extinguishing system.
This device is easy to use that it can operate as long as there is pressure water. It can also used with hydrant system that to connect the outlet of the hydrant. The foam extinguishing system is used to the liquid combustibles fire and insoluble and uncharged solid combustibles fire, for the charged solid and gas combustibles fire, there are dry powder extinguisher available in this system.
Range of Application:
1. Highway tunnel, railway tunnel.
2. Chemical factory workshop, storeroom, garage, hangar.
3. Marine, wharf
4. Other crowded entertainment venues and public place.
Technical parameters:
Model |
Foam Tank Capacity (L) |
Flow Range (L/S) |
Spray DIST (m) |
Inlet Size |
Working Pressure Range (MPa) |
Expansion Ration |
PSG 30 |
30 |
0.56~0.68 |
≥6 |
DN25 |
0.6~0.8 |
≥4 |
PSG 50 |
50 |
Notes: we make available customized design for our clients
The PSG series Outside foam hydrant cabinet is mainly consist of cabinet, fire hose reel, foam concentrate tank, proportioner, foam gun and dry powder extinguisher. It can either apply in foam extinguishing system or water spray extinguishing system. Close the foam valve and put out the fire with water when applied as water spray extinguishing system.
This device is easy to use that it can operate as long as there is pressure water. It can also used with hydrant system that to connect the outlet of the hydrant. The foam extinguishing system is used to the liquid combustibles fire and insoluble and uncharged solid combustibles fire, for the charged solid and gas combustibles fire, there are dry powder extinguisher available in this system.
Range of Application:
1. Highway tunnel, railway tunnel.
2. Chemical factory workshop, storeroom, garage, hangar.
3. Marine, wharf
4. Other crowded entertainment venues and public place.
Technical parameters:
Model |
Foam Tank Capacity (L) |
Flow Range (L/S) |
Spray DIST (m) |
Inlet Size |
Working Pressure Range (MPa) |
Expansion Ration |
PSG 30 |
30 |
0.56~0.68 |
≥6 |
DN25 |
0.6~0.8 |
≥4 |
PSG 50 |
50 |
Notes: we make available customized design for our clients